How do you test a TPR valve on a water heater?

3 min read

Asked by: Felicia Campbell

To test the TPR valve, simply lift it up and down several times. This should lift the attached brass stem and hot water should get flow out of the drainpipe. You should hear a gurgling sound as the valve allows some water to be released into the drain tube.Aug 28, 2018

How do you know if your pressure relief valve is faulty?

Now, here are five symptoms that could indicate that your pressure reducing valve is going bad.

  1. Low or Fluctuating Water Pressure. …
  2. No Water Pressure. …
  3. Hammering or Vibrating Noises. …
  4. A Leak in your Flower Bed. …
  5. High Water Pressure.


Should TPR valve be hot?

The T&P valve, or temperature and pressure relief valve, is one of the most important safety devices in your home. If the temperature rises above 210 degrees Fahrenheit or the pressure exceeds 150 psi, the valve will open and relieve the pressure inside the tank.
May 22, 2015

Should you test pressure relief valve?

It is recommended that you test pressure relief valves at least once every six months, especially to reduce leakage caused by the buildup of minerals and corrosion. Scheduling pressure relief valve testing every six months enables you to troubleshoot issues and fix them promptly.
Feb 8, 2022

Is it normal for water to come out of pressure relief valve?

While it’s normal for some water to leak from the pressure relief valve, the unit itself should never leak water. This can happen when the valve doesn’t properly relieve pressure from the unit and, in response, the tank ruptures.
Feb 2, 2022

How do you test a T&P relief valve?


Simply place a bucket beneath the discharge tube. You just want to flip open the relief valve. And let it run for about five seconds to make sure it opens fully.

How do I know if my pressure relief valve is bad on my water heater?

Excessive noise: If your hot water heater is rattling or emitting a high-pitched whistling noise, it’s likely the sound of steam trying to escape the tank, which is a sign of far too much pressure pressing against the inner walls. This means the relief valve isn’t doing its job and may need replacing.
Aug 14, 2020

What happens when a pressure relief valve fails?

If a pressure relief valve experiences failure, is releasing pressure before a system reaches maximum pressure, or is constantly leaking or chattering, it’s always best to assume that there’s something wrong with the system.
Feb 26, 2020

How often should pressure relief valves be replaced?

every 4-5 years

Make sure you replace your PRV every 4-5 years to avoid problems due to age.

What PSI should a pressure relief valve be?

The relief valve setting(s) should be at least 10% or 15-psig, whichever is greater, above the maximum operating pressure.
Nov 4, 2020

What psi level is the safety relief valve set to open at?

Explanation The safety valve protects air tanks and the rest of an air brake system from accumulating too much air pressure. The safety valve is usually set to open at 150 psi.

What causes too much pressure in hot water heater?

In short, when the temperature or pressure of the water heater gets too high, the valve opens, and releases water that’s causing the increase in pressure. The problem is that many homeowners don’t realize they need to be testing their T&P valves every 6 months, and replacing them every 5 years.