What causes a light ballast to go bad? - Project Sports
Nederlands | English | Deutsch | Türkçe | Tiếng Việt

Project Sports

Questions and answers about sports

What causes a light ballast to go bad?

6 min read

Asked by: Rob Corona

Ballast failure is often caused by the surrounding environment—mainly heat and moisture. When it’s too hot or too cold, a ballast can burn or fail to start your lamps. Heat, along with continuous condensation inside an electronic ballast, can cause corrosion over time.

What are the signs of a bad ballast?

If your fluorescent lighting is displaying any of the signs below, it could be a symptom of a bad ballast:

  • Flickering. …
  • Buzzing. …
  • Delayed start. …
  • Low output. …
  • Inconsistent lighting levels. …
  • Switch to an electronic ballast, keep lamp. …
  • Switch to an electronic ballast, switch to a T8 fluorescent.

How long do ballasts last?

12 to 15 years

According to the Certified Ballast Manufacturers Association, the average magnetic ballast lasts about 75,000 hours, or 12 to 15 years with normal use. The optimum economic life of a fluorescent lighting system with magnetic ballasts is usually about 15 years.

Can you fix a bad ballast?

If you can change out a light switch or outlet you can definitely replace an old ballast that doesn’t work. As I said in the beginning, you’ll save yourself $75 to $90 doing this fix yourself.

How do you troubleshoot a ballast?

You want to set your one of your leads on the white wire that's the power coming into the ballast.

How do you troubleshoot a fluorescent light ballast?

How to Check If the Ballast Is Bad in Fluorescent Lighting

  1. Turn off the fluorescent fixture’s circuit breaker inside the breaker panel. …
  2. Remove the fluorescent bulbs from the fixture. …
  3. Remove the ballast cover from the fixture, if the ballast is not already exposed. …
  4. Set the multimeter to the ohm setting.

How much does a new ballast cost?

A replacement ballast costs about $10-25 depending on capacity and brand. The bite is that an electrician trip charge (which includes 30 or 60 minutes work) is going to be $75-150 probably – for about 5 minutes work on each light fixture.

How do you check a ballast?

To measure it, set your digital multimeter to around a thousand ohms resistance setting. Connect the black leads to the white ground wire on your ballast. Afterward, test every other wire with the red lead. When you do this test, a good ballast will return an “open-loop” or max resistance.

How do you change a ballast without turning off power?

Remove the wire nut from one of the power wires and carefully strip about 1/2 inch of insulation from the end, making sure not to touch the end. Hold the ballast wire next to this wire with the stripped ends parallel but not touching. Quickly slip on the wire nut and screw onto the ends.

Will LED bulbs work if ballast is bad?

Can LED lamps work off of existing ballasts? Yes, if they have an internal driver than can work off that ballast. Philips, for example, has designed a tube that is compatible with an existing electronic ballast.

What happens when a ballast goes bad?

The ballast itself can go bad, which causes lights to flicker or even appear to be burnt out, when in fact they aren’t. They require maintenance and energy to power, on top of the power used to light the fluorescent bulb. They are a large part of the equation when using fluorescent lamps.

What happens if you wire a ballast wrong?

If a ballast fails, it can cause a short, burn out tubes or even cause a fire, so it must be replaced. Lights that don’t turn on, fluorescent tubes blackened near their ends, and brown, burnt tube electrodes are all indicators that a ballast is bad.

How many volts does a ballast put out?

Newer fluorescent ballasts are usually rated for both 120 volts and 277 volts. Some are rated for only 120 volts, others for only 277 volts (used in commercial environments).

How do you check voltage on a ballast?

Test the ballast’s voltage with a multimeter. Attach the multimeter’s leads to the sockets at the ends of the ballast. If the reading is not between five and nine volts, replace the ballast. Adjust the multimeter to measure frequency and replace the ballast if the reading is not between 20 and 50 kilohertz.

Does a ballast use electricity if no bulbs are present?

No, unlike LEDs, the fluorescent bulb itself (or rather the tube) can not use power when it burns out, however, the ballasts may use a trace of energy whether or not there is a bulb installed.

How do I choose a replacement ballast?

The only things that matter when you're replacing a ballast are we're number one the number of bulbs number two the type of bulbs number three the voltage.

How do I know if a ballast is compatible?

You can determine whether you have a compatible fixture in seconds. Simply turn the light on, then take a photo of the fixture using your smartphone or digital camera. If there are no dark bands on the resulting image, you have an electronic ballast that will work with direct drop-in LED tubes.

Are all ballast the same?

And there are two types of ballasts in each family: magnetic and electronic. Magnetic ballasts are the older ballast technology. For the fluorescent family, both T12 linear fluorescents and two-pin CFLs use magnetic ballasts. For HIDs, some metal halides and HPS lamps use magnetic ballasts.

How do I know if my ballast is T8 or T12?

If no markings are available, the size in diameter of the tube is the easiest way to determine the type you have installed. T8 tubes are 1-inch in diameter and T12 tubes are 1 1/2 -inch.

What happens if you put a T8 bulb in a T12 fixture?

T12 tubes are 1.5″ in diameter while T8s are just one inch. All other things—socket sizes, lengths, distance between pins—are the same. T8 LED tubes won’t fall out if you try to install them in a T12 fixture—they’ll fit just fine.

Why do fluorescent lights not turn on sometimes?

If a fluorescent tube neither lights nor flickers when switched on, first check to see that the fixture is plugged in and that no fuse has blown or circuit breaker has tripped. If this does not help, try wiggling the tube gently in its sockets by rocking it back and forth and from side to side.
22 сент. 1988

Can I replace a T12 ballast with a T8?

The easiest and lowest price option to replace a T12 is a T8 linear fluorescent. They have become the go-to option for pre-existing T12s. If you still have magnetic ballasts, switching to a T8 will require a ballast swap. Another option is to move forward with an LED retrofit.

Are T8 bulbs being discontinued?

Even some T8 lamps have been phased out. US Congress has enacted legislation to prohibit the manufacture of these and other inefficient lighting technologies, and is calling for manufacturers to meet minimum efficiency requirements and lumens per watt for new products.

Can I replace T12 with LED?

Can you actually retrofit T12 to LED without changing out the ballast? Actually, yes. But before you make a decision, there are other LED solutions to consider for a high-efficiency lighting option for existing T12s. A lot has changed in just a few years in the lighting industry.