Asked by: April Jordan

Formula: SWL (kg) = D2 (mm) For example: Diameter = 25 mm SWL (kg) = D2 (mm) SWL (kg) = D (mm) x D (mm) = 25 x 25 = 625 kg SWL (t) = 0.625 tonnes. The above equation can be reversed to calculate the diameter (D) in millimetres of fibre rope needed to lift a given load.

What is the formula for estimating the safe working load of a wire rope sling?

Once you know the diameter of the rope, you can apply it to the formula, which is SWL = D2 x 8. D represents the diameter of the rope in inches. If you’re working with a 1.5-inch diameter cable, for example, then the formula would be SWL = 1.52 x 8 or SWL = 2.25 x 8.

What is the working load limit of a 1/2 wire rope sling?

Wire Rope Sling Capacity Chart

Wire Rope Slings – Mechanically Spliced XIP Rope
Rated Loads ( Tons – 2000 Lbs. )
1/2 2.5 5.1
9/16 3.2 6.4
5/8 3.9 7.8

How is load limit calculated?

The WLL is calculated by dividing MBL by a safety factor (SF). An example of this would be a chain that has a MBL of 2000 lbf (8.89 kN) would have a SWL or WLL of 400 lbf (1.78 kN) if a safety factor of 5 (5:1, 5 to 1, or 1/5) is used.

How do you calculate load lifting capacity?

Calculating the Weight of a Load

  1. Step 1: Determine the Volume of the Load. Rectangle/Square: Volume = Length x Width x Height. …
  2. Step 2: Determine the Material You’ll Be Lifting. The table below can be used for approximate weight values of common loads and materials: …
  3. Step 3: Determine the Weight of Object.

What should be used to determine the capacity of a sling?

Multiple leg slings show the Rated Capacity when the angle between any leg and the horizontal is 600 45° and 30°. The Rated Capacity of a sling decreases as the leg angle increases.
RATED CAPACITY CHART.

LARGEST ANGLE ANY LEG AND HORIZONTAL CAPACITY REDUCTION FACTOR (COSINE)
90° 1.000
85° 0.96
80° .985
75° .966

How do you calculate wire rope strength?

The basic breaking strength factor for manila line is found by multiplying the square of the circumference of the line by 900 lbs. When you purchase line you will buy it by its diameter. However, for purposes of the USCG license exams, all lines must be measured by circumference.

What is the working load limit of a sling that has a breaking strength of 10000 pounds?

The Working Load Limit is factored by using one-third of the straps breaking strength. For example, 10,000 pound breaking strength of force before failure would result in a 3,333 lb working load limit.

How do you calculate load?

Multiply the mass of the object by the gravitational acceleration of the earth (9.8 m/sec2), and the height in meters. This equation is the object at rest’s potential energy. Potential energy is measured in joules; this is the load force.